Sujahath Siddeek
All work

TeardownMar 2025 to nowSoftware Engineer, Blue Brand

Battery energy platform

The production backend and edge controller for a home battery system: an inverter, a smart meter and a BMS on one Raspberry Pi 5.

Company work. The code is private.

Company work, code is private
Raspberry Pi 5edge controller9600 baudDTSU666 meterfixed 9600 baud115200 baudJK BMScustom protocolSeparate buses, because the two can't run at one speed.
The wiring finding: the meter and the BMS can't share one RS485 bus.
device polling failures after debugging the link
80% to 0%
devices on Modbus RTU: inverter, meter and BMS
3
BMS modules in the docs, against one polled in code, found in review
16

Wire the bus

Try putting the meter and the BMS on one RS485 bus, then split them. The baud rates are the ones measured on the hardware.

Raspberry Pi 5Modbus master9600 baudDTSU666 meterreplyingJK BMScan't parse frames
  • DTSU666 meterOK
  • JK BMSUnreadable

At 9600 baud the meter answers, but the BMS speaks its own protocol at 115200, so it never gets a frame it understands.

Found on the hardware before deployment, alongside an architecture review of the control loop.

The problem

A home battery system has three devices that each speak their own dialect of Modbus: a Deye inverter, a DTSU666 smart meter and a JK BMS. The platform has to read them reliably, control the battery safely and report to the cloud.

How I built it

FastAPI services in production, with PostgreSQL and TimescaleDB for telemetry, MQTT, Docker and GitLab CI/CD.

A Python controller on a Raspberry Pi 5 talks Modbus RTU over RS485 to all three devices and runs the control loop.

REST, WebSocket and MQTT integrations with retry and fallback, and a control-panel dashboard in Vue 3, TypeScript and Tailwind.

What happened

  • Debugging the device link cut polling failures from about 80% to 0%.
  • A pre-deployment architecture review found that the control loop's verify step was never wired into execution, and that the code polled one BMS while the docs described 16 modules.
  • Hardware testing showed the meter is fixed at 9600 baud while the BMS speaks a custom protocol at 115200, so the two can't share one RS485 bus. That changed the wiring design.

Architecture

Cloud backendFastAPI, TimescaleDBDashboardVue 3, TypeScriptRaspberry Pi 5edge controllerDeye inverterDTSU666 meterfixed 9600 baudJK BMScustom, 115200 baudMQTTREST, WebSocketRS485, Modbus RTU
  • Python
  • FastAPI
  • PostgreSQL
  • TimescaleDB
  • MQTT
  • Modbus RTU
  • Raspberry Pi 5
  • Docker
  • GitLab CI
  • Vue 3
  • TypeScript

Next teardown

A public IP behind CGNAT

WireGuard through carrier-grade NAT